Tutorial Creep Application
This short tutorial shows how to load the bundled creep examples and inspect the main creep-compliance views. It does not require fitting a theory.
Load Creep Data
Start RepTate and create a new Creep application.
Open one of the example files in
data/Creep:Maxwell.creepCM3_Creep.creepCM3_CreepRecovery.creep
The Creep application reads text files with the
.creepextension. The file parameters include the appliedstressand may also include parameters such asMwandT. The data columns used by the application are timetand strainstrain.
Inspect Views
Use the View selector to switch between the creep representations:
gamma(t)plots the measured strain as a function of time.log(gamma(t))plotslog10(t)againstlog10(abs(gamma)).J(t)plots the creep compliance, calculated as \(J(t)=\gamma(t)/\sigma_0\), where \(\sigma_0\) is the appliedstressfile parameter.log(J(t))shows the same compliance on logarithmic transformed axes.t/J(t)plots time divided by compliance, which is useful for inspecting the approach to steady viscosity.
The i-Rheo views transform the compliance data to obtain
\(G'(\omega)\) and \(G''(\omega)\). When one of these views is selected,
RepTate shows extra controls for the steady-state viscosity and the time range
used by the transformation; the oversampled i-Rheo view also shows the
oversampling control.
Fit retardation modes
Select a single creep data file in the data set. The
Retardation Modestheory is initialized from the first active file, so keep only the file you want to fit active when setting up the theory.In the theory selector, choose
Retardation Modesand create the theory. The initial modes are distributed logarithmically between the smallest positive time and the largest time in the selected file.Use the mode spinbox in the theory toolbar to change the number of modes. The theory documentation recommends roughly one mode per decade as a useful starting point for modes intended for flow simulations.
Click
Calculateto evaluate the current parameters, orMinimize Errorto fit the instantaneous compliancelogJini, terminal viscositylogeta0, the time rangelogtmin/logtmax, and the mode compliance valueslogJ00,logJ01, etc.When the mode markers are visible, drag the yellow points to adjust the mode compliances. Dragging the leftmost and rightmost modes changes the fitted time range.